Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.908
Filtrar
1.
Crit Care Explor ; 6(5): e1083, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38694846

RESUMO

OBJECTIVES: This prospective cohort study aimed to investigate changes in intracranial pressure (ICP) and cerebral hemodynamics in infants with congenital heart disease undergoing the Glenn procedure, focusing on the relationship between superior vena cava pressure and estimated ICP. DESIGN: A single-center prospective cohort study. SETTING: The study was conducted in a cardiac center over 4 years (2019-2022). PATIENTS: Twenty-seven infants with congenital heart disease scheduled for the Glenn procedure were included in the study, and detailed patient demographics and primary diagnoses were recorded. INTERVENTIONS: Transcranial Doppler (TCD) ultrasound examinations were performed at three time points: baseline (preoperatively), postoperative while ventilated (within 24-48 hr), and at discharge. TCD parameters, blood pressure, and pulmonary artery pressure were measured. MEASUREMENTS AND MAIN RESULTS: TCD parameters included systolic flow velocity, diastolic flow velocity (dFV), mean flow velocity (mFV), pulsatility index (PI), and resistance index. Estimated ICP and cerebral perfusion pressure (CPP) were calculated using established formulas. There was a significant postoperative increase in estimated ICP from 11 mm Hg (interquartile range [IQR], 10-16 mm Hg) to 15 mm Hg (IQR, 12-21 mm Hg) postoperatively (p = 0.002) with a trend toward higher CPP from 22 mm Hg (IQR, 14-30 mm Hg) to 28 mm Hg (IQR, 22-38 mm Hg) postoperatively (p = 0.1). TCD indices reflected alterations in cerebral hemodynamics, including decreased dFV and mFV and increased PI. Intracranial hemodynamics while on positive airway pressure and after extubation were similar. CONCLUSIONS: Glenn procedure substantially increases estimated ICP while showing a trend toward higher CPP. These findings underscore the intricate interaction between venous pressure and cerebral hemodynamics in infants undergoing the Glenn procedure. They also highlight the remarkable complexity of cerebrovascular autoregulation in maintaining stable brain perfusion under these circumstances.


Assuntos
Circulação Cerebrovascular , Cardiopatias Congênitas , Hemodinâmica , Pressão Intracraniana , Ultrassonografia Doppler Transcraniana , Humanos , Lactente , Estudos Prospectivos , Feminino , Masculino , Pressão Intracraniana/fisiologia , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Hemodinâmica/fisiologia , Estudos de Coortes , Técnica de Fontan , Veia Cava Superior/fisiopatologia , Veia Cava Superior/diagnóstico por imagem
2.
Emerg Med Pract ; 26(Suppl 4): 1-28, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38652756

RESUMO

Acute stroke is one of the most common neurologic emergencies encountered by emergency clinicians. While point of care ultrasound has been a core part of emergency clinicians' training and practice for many years, the use of specialized ultrasound modalities in the care of acute ischemic stroke has not been as widely adopted. This review discusses the use of ultrasound in acute stroke, with a focus on applications of interest to emergency clinicians. Transcranial Doppler, carotid Doppler, microembolic signal detection, transthoracic echocardiography, evaluation for collateral circulation and optic nerve sheath diameter measurement are discussed in a case-based format, with a focus on practical applications for emergency clinicians.


Assuntos
Serviço Hospitalar de Emergência , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia Doppler Transcraniana/métodos , Sistemas Automatizados de Assistência Junto ao Leito
3.
Neuroimaging Clin N Am ; 34(2): 191-202, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38604704

RESUMO

Ultrasound evaluation of the brain is performed through acoustic windows. Transcranial Doppler has long been used to monitor patients with subarachnoid hemorrhage for cerebral vasospasm. Transcranial color-coded sonography permits parenchymal B-mode imaging and duplex evaluation. Transcranial ultrasound may also be used to assess the risk of delayed cerebral ischemia, screen patients for the presence of elevated intracranial pressure, confirm the diagnosis of brain death, measure midline shift, and detect ventriculomegaly. Transcranial ultrasound should be integrated with other point-of-care ultrasound techniques as an essential skill for the neurointensivist.


Assuntos
Isquemia Encefálica , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Hemorragia Subaracnóidea/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Encéfalo
4.
Clin Neurol Neurosurg ; 240: 108240, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38554529

RESUMO

BACKGROUND: IIH is a severe form of headache that often has superimposed migraine and often it is very difficult to distinguish the two forms of headache. Intracranial hemodynamics is a relatively unexplored means of distinguishing between the two forms of headache. OBJECTIVES: We aimed to study intracranial flow dynamics using Transcranial Doppler in patients with IIH, migraine, and normal controls. MATERIALS AND METHODS: It was a hospital-based observational study that included 51 people with IIH, 87 people with migraine, and 101 healthy controls and all were subjected to TCD study after detailed clinical examination. RESULTS: Mean age of patients in three groups were similar with the mean age in IIH being 33.41 ± 10.75 (age in years ± SD). Vision loss was present in 66.67% of patients with IIH, and most common field defect was generalized constriction (27.5%). Neuroimaging was abnormal in 94.11% of patients of IIH with mean CSF pressure was 31.27±5.32 cm of water. Of all the TCD-measured velocities, mean flow velocity (MFV) showed a significant difference in all three groups with (p-value <0.001). The pulsatility index, both for middle cerebral arteries as well as ophthalmic arteries showed a significant difference in the three groups with the highest values in IIH patients (p-value<.001). The mean VMR in IIH (1.11±0.32) was lower than the mean VMR in migraine (1.34±0.43) as well as controls (1.49±0.46). CONCLUSION: TCD parameters like MFV and PI are useful parameters that show considerable variation and can be used to differentiate between IIH and migraine.


Assuntos
Transtornos de Enxaqueca , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Transtornos de Enxaqueca/diagnóstico por imagem , Transtornos de Enxaqueca/fisiopatologia , Masculino , Adulto , Feminino , Pessoa de Meia-Idade , Circulação Cerebrovascular/fisiologia , Adulto Jovem , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia
5.
Med Intensiva (Engl Ed) ; 48(3): 165-173, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38431382

RESUMO

Transcranial ultrasonography is a non-invasive, bedside technique that has become a widely implemented tool in the evaluation and management of neurocritically ill patients. It constitutes a technique in continuous growth whose fundamentals (and limitations) must be known by the intensivist. This review provides a practical approach for the intensivist, including the different sonographic windows and planes of insonation and its role in different conditions of the neurocritical patients and in critical care patients of other etiologies.


Assuntos
Ultrassonografia Doppler em Cores , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Cuidados Críticos
6.
Artigo em Russo | MEDLINE | ID: mdl-38465805

RESUMO

Functional transcranial dopplerography (FTCD) is a non-invasive ultrasound examination that allows recording the dynamics of cerebral blood flow parameters under conditions of factors stimulated the activity of the structures of the central nervous system. Judgments about the sensitivity and specificity of FTCD are based on the close connection between changes in the activity of the nervous (somatic) system and the response of regional cerebral blood flow (CBF). The technique is a portable and accessible diagnostic method used in assessing the possibility of expanding functional activity during the recovery period after a stroke. An increase in mental activity in response to the presentation of a cognitive task, accompanied by an increase in glucose and oxygen consumption and naturally requiring an increase in cerebral perfusion parameters, can also be assessed by changes in regional blood flow parameters while maintaining the reactive mechanisms of autoregulation. A search of literature sources was carried out in the electronic databases PubMed and Scopus. For the subject search, Medical Subject Headings were used. A total of 36 sources that mentioned the terms «cognitive function¼ and «functional transcranial Doppler¼ were selected for preliminary analysis. At the present stage, methodological problems are obvious, requiring the development and implementation of a standard package of targeted functional tests to assess cognitive status. Available equipment and software require technological solutions to ensure objective recording of changes in cerebral blood flow during testing and training.


Assuntos
Disfunção Cognitiva , Acidente Vascular Cerebral , Humanos , Cognição , Circulação Cerebrovascular , Disfunção Cognitiva/diagnóstico por imagem , Síndrome , Ultrassonografia Doppler Transcraniana/métodos
7.
Br J Anaesth ; 132(6): 1260-1273, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38471987

RESUMO

Cerebral blood flow (CBF) autoregulation is the physiologic process whereby blood supply to the brain is kept constant over a range of cerebral perfusion pressures ensuring a constant supply of metabolic substrate. Clinical methods for monitoring CBF autoregulation were first developed for neurocritically ill patients and have been extended to surgical patients. These methods are based on measuring the relationship between cerebral perfusion pressure and surrogates of CBF or cerebral blood volume (CBV) at low frequencies (<0.05 Hz) of autoregulation using time or frequency domain analyses. Initially intracranial pressure monitoring or transcranial Doppler assessment of CBF velocity was utilised relative to changes in cerebral perfusion pressure or mean arterial pressure. A more clinically practical approach utilising filtered signals from near infrared spectroscopy monitors as an estimate of CBF has been validated. In contrast to the traditional teaching that 50 mm Hg is the autoregulation threshold, these investigations have found wide interindividual variability of the lower limit of autoregulation ranging from 40 to 90 mm Hg in adults and 20-55 mm Hg in children. Observational data have linked impaired CBF autoregulation metrics to adverse outcomes in patients with traumatic brain injury, ischaemic stroke, subarachnoid haemorrhage, intracerebral haemorrhage, and in surgical patients. CBF autoregulation monitoring has been described in both cardiac and noncardiac surgery. Data from a single-centre randomised study in adults found that targeting arterial pressure during cardiopulmonary bypass to above the lower limit of autoregulation led to a reduction of postoperative delirium and improved memory 1 month after surgery compared with usual care. Together, the growing body of evidence suggests that monitoring CBF autoregulation provides prognostic information on eventual patient outcomes and offers potential for therapeutic intervention. For surgical patients, personalised blood pressure management based on CBF autoregulation data holds promise as a strategy to improve patient neurocognitive outcomes.


Assuntos
Circulação Cerebrovascular , Homeostase , Humanos , Homeostase/fisiologia , Circulação Cerebrovascular/fisiologia , Pressão Intracraniana/fisiologia , Monitorização Fisiológica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia Doppler Transcraniana/métodos
8.
J Neuroimaging ; 34(3): 348-355, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38553906

RESUMO

BACKGROUND AND PURPOSE: Thresholds for abnormal transcranial Doppler cerebrovascular reactivity (CVR) studies are poorly understood, especially for patients with cerebrovascular disease. Using a real-world cohort with cerebral arterial stenosis, we sought to describe a clinically significant threshold for carbon dioxide reactivity (CO2R) and vasomotor range (VMR). METHODS: CVR studies were performed during conditions of breathing room air normally, breathing 8% carbon dioxide air mixture, and hyperventilation. The mean and standard deviation (SD) of CO2R and VMR were calculated for the unaffected side in patients with unilateral stenosis; a deviation of 2 SDs below the mean was chosen as the threshold for abnormal. Receiver operating characteristic (ROC) curves for both sides for patients with unilateral and bilateral stenosis were evaluated for sensitivity (Sn) and specificity (Sp). RESULTS: A total of 133 consecutive CVR studies were performed on 62 patients with stenosis with mean±SD age 55±16 years. Comorbidities included hypertension (60%), diabetes (15%), stroke (40%), and smoking (35%). In patients with unilateral stenosis, mean±SD CO2R for the unaffected side was 1.86±0.53%, defining abnormal CO2R as <0.80%. Mean±SD CO2R for the affected side was 1.27±0.90%. The CO2R threshold predicted abnormal acetazolamide single-photon emission computed tomography (SPECT) (Sn = .73, Sp = .79), CT/MRI perfusion abnormality (Sn = .42, Sp = .77), infarction on MRI (Sn = .45, Sp = .76), and pressure-dependent exam (Sn = .50, Sp = .76). For the unaffected side, mean±SD VMR was 39.5±15.8%, defining abnormal VMR as <7.9%. For the affected side, mean±SD VMR was 26.5±17.8%. The VMR threshold predicted abnormal acetazolamide SPECT (Sn = .46, Sp = .94), infarction on MRI (Sn = .27, Sp = .94), and pressure-dependent exam (Sn = .31, Sp = .90). CONCLUSIONS: In patients with multiple vascular risk factors, a reasonable threshold for clinically significant abnormal CO2R is <0.80% and VMR is <7.9%. Noninvasive CVR may aid in diagnosing and risk stratifying patients with stenosis.


Assuntos
Circulação Cerebrovascular , Sensibilidade e Especificidade , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/fisiopatologia , Dióxido de Carbono , Reprodutibilidade dos Testes , Idoso , Velocidade do Fluxo Sanguíneo , Relevância Clínica
9.
Ultrasound Med Biol ; 50(5): 751-759, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38418342

RESUMO

OBJECTIVE: Neurovascular coupling (NVC) represents the increase in regional blood flow associated with neural activity. The aim here was to describe a new approach to non-invasive measurement of NVC by spectral analysis of the cerebral blood flow velocity (CBFV) with transcranial Doppler. METHODS: In a sample of 20 healthy participants, we monitored systolic CBFV in the left posterior cerebral artery (PCA) during off (eyes closed) and on (flickering checkerboard) periods. The contralateral middle cerebral artery was simultaneously monitored as a control. Each participant was submitted to three experiments, each having five cycles, with increasing duration of the cycles, from 10 s (0.1 Hz) to 20 s (0.05 Hz) and lastly 40 s (0.025 Hz), half the time for on and for off periods, constituting a total of 6 min. The successive cycles were expected to cause oscillation in CBFV in a sinusoidal pattern that could be characterized by spectral analysis. We also measured the classic CBFV overshoot as the relative increase in percentage of systolic CBFV from baseline. The relationship and agreement between the two methods were analyzed by linear regression and Bland-Altman plots. In every participant, a clear peak of amplitude in the PCA CBFV spectrum was discernible at 0.1, 0.05 and 0.025 Hz of visual stimulation. RESULTS: On average, this amplitude was 7.1 ± 2.3%, 10.9 ± 3.5% and 17.3 ± 6.5%, respectively. This response contrasted significantly with an absent peak in middle cerebral artery monitoring (p < 0.0001). The spectral amplitude and classic overshoot were highly correlated and linearly related (p < 0.0001). CONCLUSION: NVC can be quantified by the spectral amplitude of PCA CBFV at slower and higher frequencies of visual stimulation. This method represents an alternative to classic overshoot without the need for stimulus marking or synchronization.


Assuntos
Acoplamento Neurovascular , Humanos , Acoplamento Neurovascular/fisiologia , Artéria Cerebral Média/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Voluntários Saudáveis , Circulação Cerebrovascular/fisiologia
10.
J Stroke Cerebrovasc Dis ; 33(3): 107575, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38232582

RESUMO

AIM: This study aimed to evaluate the feasibility of transcranial color-coded sonography (TCCS) and contrast-enhanced ultrasound (CEUS) in assessing middle cerebral artery (MCA) stem stenosis or occlusion compared to digital subtraction angiography (DSA). METHODS: A total of 48 cases including 96 MCAs suspected stem stenosis or obstruction in the MCA were assessed by TCCS, CE-TCCS, and DSA. The diameters of the most severe stenosis (Ds), proximal normal artery (Dn), and diameter stenosis rate of MCA were measured using both the color doppler flow imaging (CDFI) modality of TCCS or CEUS and the CEUS imaging modality. The intraclass correlation coefficients (ICCs) and 95 % confidence intervals (CI) were evaluated, and a weighted Kappa value was used to evaluate the intra-observer agreement, inter-observer agreement, agreement between CDFI modality and DSA stenosis or occlusion, and agreement between CEUS imaging modality and DSA stenosis or occlusion. RESULTS: The ICC results indicated excellent repeatability and reproducibility (all ICCs > 0.75; weighted Kappa values >0.81). Compared with DSA, the weighted Kappa values and 95 % CIs of stenosis (the first measurement was taken by two observers) of CDFI modality and CEUS imaging modality were 0.175 (0.041, 0.308) and 0.779 (0.570, 0.988) for observers A and 0.181 (0.046, 0.316) and 0.779 (0.570, 0.988) for observers B respectively. CONCLUSION: This study indicates that inter- and intra-observer agreements were good for the direct method of measuring percentages of MCA stenosis by TCCS and CEUS. CEUS imaging modality is a new and reliable imaging modality approach to evaluate the MCAs stenosis and occlusion.


Assuntos
Transtornos Cerebrovasculares , Artéria Cerebral Média , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Constrição Patológica , Angiografia Digital/métodos , Reprodutibilidade dos Testes , Estudos de Viabilidade , Ultrassonografia Doppler Transcraniana/métodos , Sensibilidade e Especificidade
11.
Microsc Res Tech ; 87(5): 948-956, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38174664

RESUMO

Agitated saline microbubbles (MBs) are a common contrast agent for determining right-to-left shunt (RLS) by the contrast transcranial Doppler (c-TCD). The size of the generated bubbles is not standardized in clinical practice. MBs were generated using the recommended manual method by reciprocating motion through two syringes. The bubble size distributions (BSD) were measured using the microscopic shadow imaging technique. The results show that the diameter of MBs is mainly distributed between 10 and 100 µm, the mean bubble size is between 21 and 34 µm, the Sauter mean diameter (D32) is primarily between 50 and 300 µm, and the standard deviation (SD) is between 6 and 17 µm in 80 experiments. It provides a more accurate basis for the recommended manual method instability. The high variance values of the BSD indicate that the manual method has low stability and repeatability. The results of this study can be useful for further improvement of the reliability of c-TCD in detecting RLS. RESEARCH HIGHLIGHTS: This study provided the first detailed descriptions of the MBs size distribution in a flowing contrast agent by the microscopic shadow imaging technique. It reveals significant differences in the bubble size of manual foaming during repeated manipulations for each individual and between individuals.


Assuntos
Meios de Contraste , Microbolhas , Humanos , Reprodutibilidade dos Testes , Ultrassonografia Doppler Transcraniana/métodos
12.
Neurocrit Care ; 40(1): 130-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37160846

RESUMO

BACKGROUND: Noninvasive neuromonitoring in critically ill children includes multiple modalities that all intend to improve our understanding of acute and ongoing brain injury. METHODS: In this article, we review basic methods and devices, applications in clinical care and research, and explore potential future directions for three noninvasive neuromonitoring modalities in the pediatric intensive care unit: automated pupillometry, near-infrared spectroscopy, and transcranial Doppler ultrasonography. RESULTS: All three technologies are noninvasive, portable, and easily repeatable to allow for serial measurements and trending of data over time. However, a paucity of high-quality data supporting the clinical utility of any of these technologies in critically ill children is currently a major limitation to their widespread application in the pediatric intensive care unit. CONCLUSIONS: Future prospective multicenter work addressing major knowledge gaps is necessary to advance the field of pediatric noninvasive neuromonitoring.


Assuntos
Lesões Encefálicas , Ultrassonografia Doppler Transcraniana , Humanos , Criança , Ultrassonografia Doppler Transcraniana/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Estado Terminal , Unidades de Terapia Intensiva Pediátrica , Estudos Multicêntricos como Assunto
13.
Clin Neurol Neurosurg ; 236: 108074, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38091703

RESUMO

BACKGROUND: Transcranial Sonography is a non-invasive technique that has been used as a diagnostic tool for a variety of neurodegenerative disorders. However, the utility and potential application of this technique in NBIA disorders is scarce and inconclusive. METHODS: In this cross-sectional retrospective case-control study, the echogenicity of Substantia Nigra (SN), Lentiform Nucleus (LN), and Diameter of the Third Ventricle (DTV) were assessed by TCS in genetically confirmed NBIA patients referring to the movement disorder clinic. The normal echogenicity area of SN was defined based on the 90th percentile of an age-and-gender-matched control group. NBIA patients underwent neurologic examination at each visit, but their brain magnetic resonance imaging and demographics were extracted from electronic records. RESULTS: Thirty-five NBIA patients of four subtypes with a mean disease duration of 10.54 years and 35 controls were enrolled. The normally defined SN echogenicity in controls was 0.23 cm2. DTV and SN echogenicity areas were significantly higher in patients compared to the controls (P = 0.002 and < 0.001, respectively). Around 85% and 63% of the patients showed LN and SN hyperechogenicity at least on one side, respectively. Disease duration was positively correlated with DTV (r = 0.422, p = 0.015). Cases with Pantothenate Kinase Associated Neurodegeneration (n = 23) also had significantly higher DTV and SN echogenicity area compared to the controls. CONCLUSION: Despite most NBIA patients displayed increased DVT and higher SN and LN hyperechogenicity than healthy controls, the discriminatory role of TCS on different NBIA subtypes remains to be determined.


Assuntos
Corpo Estriado , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Estudos de Casos e Controles , Estudos Transversais , Estudos Retrospectivos , Ultrassonografia , Ferro
14.
Biomech Model Mechanobiol ; 23(1): 255-269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37805938

RESUMO

Cerebrovascular haemodynamics are sensitive to multiple physiological stimuli that require synergistic response to maintain adequate perfusion. Understanding haemodynamic changes within cerebral arteries is important to inform how the brain regulates perfusion; however, methods for direct measurement of cerebral haemodynamics in these environments are challenging. The aim of this study was to assess velocity waveform metrics obtained using transcranial Doppler (TCD) with flow-conserving subject-specific three-dimensional (3D) simulations using computational fluid dynamics (CFD). Twelve healthy participants underwent head and neck imaging with 3 T magnetic resonance angiography. Velocity waveforms in the middle cerebral artery were measured with TCD ultrasound, while diameter and velocity were measured using duplex ultrasound in the internal carotid and vertebral arteries to calculate incoming cerebral flow at rest, during hypercapnia and exercise. CFD simulations were developed for each condition, with velocity waveform metrics extracted in the same insonation region as TCD. Exposure to stimuli induced significant changes in cardiorespiratory measures across all participants. Measured absolute TCD velocities were significantly higher than those calculated from CFD (P range < 0.001-0.004), and these data were not correlated across conditions (r range 0.030-0.377, P range 0.227-0.925). However, relative changes in systolic and time-averaged velocity from resting levels exhibited significant positive correlations when the distinct techniques were compared (r range 0.577-0.770, P range 0.003-0.049). Our data indicate that while absolute measures of cerebral velocity differ between TCD and 3D CFD simulation, physiological changes from resting levels in systolic and time-averaged velocity are significantly correlated between techniques.


Assuntos
Artérias Cerebrais , Hidrodinâmica , Humanos , Artérias Cerebrais/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia
15.
Neurocrit Care ; 40(2): 562-567, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37415022

RESUMO

BACKGROUND: Despite breakthroughs in stroke treatment, some patients still experience large infarctions of the cerebral hemispheres resulting in mass effect and tissue displacement. The evolution of mass effect is currently monitored using serial computed tomography (CT) imaging. However, there are patients who are ineligible for transport, and there are limited options for bedside monitoring of unilateral tissue shift. METHODS: We used fusion imaging for overlaying transcranial color duplex with CT angiography. This method allows overlay of live ultrasound on top of CT or magnetic resonance imaging scans. Patients with large hemispheric infarctions were eligible to participate. Position data from the source files were used and matched with live imaging and correlation to magnetic probes on the patient's forehead and ultrasound probe. Shift of cerebral parenchyma, displacement of the anterior cerebral arteries, basilary artery and third ventricle were analyzed, as well as pressure on the midbrain, and the displacement of the basilar artery on the head were analyzed. Patients received multiple examinations in addition to standard care of treatment with CT imaging. RESULTS: The sensitivity for diagnosing a shift of 3 mm with fusion imaging was 100%, with a specificity of 95%. No side effects or interactions with critical care equipment were recorded. CONCLUSIONS: Fusion imaging is an easy method to access and acquire measurements for critical care patients and follow-up of tissue and vascular displacement after stroke. Fusion imaging may be a decisive support for indicating hemicraniectomy.


Assuntos
Pressão Intracraniana , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico , Tomografia Computadorizada por Raios X , Artéria Cerebral Anterior , Infarto , Ultrassonografia Doppler Transcraniana/métodos
16.
Arch Dis Child Educ Pract Ed ; 109(2): 98-104, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-37532292

RESUMO

Transcranial Doppler (TCD) ultrasound is a non-invasive neuromonitoring technique that falls under the umbrella of point-of-care ultrasound. In this article, we provide a primer to encourage clinicians to perform TCD examinations and to aid them with accurately interpreting the scans. We focus on the middle cerebral artery waveforms and use traumatic brain injury as a model for brain insult.


Assuntos
Lesões Encefálicas Traumáticas , Lesões Encefálicas , Criança , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Lesões Encefálicas/diagnóstico por imagem , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos
17.
J Ultrasound Med ; 43(2): 315-322, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37902179

RESUMO

PURPOSE: Aneurysmal subarachnoid hemorrhage (aSAH) is associated with high morbidity and mortality, which is largely attributable to secondary complications such as vasospasm and subsequent delayed cerebral ischemia. Transcranial Doppler (TCD) is recommended for the screening of vasospasm; however, technicians are not always available. We aimed to see how feasible and reliable bedside transcranial point-of-care ultrasound (POCUS) color-coded duplex sonography was compared with formal non-imaging TCD in measuring velocities and in diagnosing vasospasm. METHODS: This was a prospective observational study that took place in the neuroscience intensive care unit at a single academic medical center. Patients with aSAH who were undergoing formal TCDs were scanned on days 2-10 of their admission by physicians of ranging ultrasound experience. Absolute velocities were compared as well as the diagnosis of vasospasm via POCUS and formal TCDs. RESULTS: A total of 226 bedside ultrasound exams were performed and compared with 126 formal TCD studies. Sonographic windows were obtained in 89.4% of patients. Scans took 6.6 minutes to complete on average by the advanced group versus 14.5 minutes in the beginner. Correlation ranged from .52 in the beginner group to .65 in the advanced. When good quality of images obtained at a depth of 4-5 cm were reviewed, correlation of mean velocities increased to .96. Overall sensitivity for diagnosing vasospasm was 75%, with a specificity of 99% and negative predictive value of 99%. CONCLUSION: Overall, POCUS TCD cannot replace a formal study performed by expert sonographers. An abbreviated POCUS scan can be performed quickly, however, particularly with more experienced operators. POCUS TCD can also feasibly detect vasospasm, and accurate velocities can be obtained by those with all levels of ultrasound experience. Care must be taken on image interpretation that velocities are obtained at an appropriate depth to ensure appropriate insonation of the MCA as well as in optimal alignment with the vessel to obtain the most accurate velocities.


Assuntos
Médicos , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Estudos Prospectivos
18.
J Clin Ultrasound ; 52(1): 78-85, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37915120

RESUMO

PURPOSE: Bacterial meningitis remains a global threat due to its high mortality. It is estimated that >1.2 million cases of bacterial meningitis are reported annually. Intracranial vasculopathy is an important, under-documented complication, easily detected by transcranial Doppler (TCD) ultrasonography. Following the PRISMA Guidelines, we reviewed the utility of TCD in bacterial meningitis. METHODS: This is a systematic review of observational studies on the use of TCD in patients with CSF-proven bacterial meningitis. Characteristic changes in TCD parameters along the course of the disease, correlation of TCD findings with neuroimaging, and functional outcomes were evaluated. RESULTS: Nine studies were included with a total of 492 participants (mean age of 42). The most common TCD finding was intracranial arterial stenosis of the MCA (50%-82%) and ischemia (33%) was the predominant neuroimaging finding. The presence of an abnormal TCD finding increased the risk of poor outcomes as high as 70%. CONCLUSIONS: Patients diagnosed with bacterial meningitis who underwent TCD show alterations in cerebral blood flow, correlating with imaging findings and poor outcomes. It aids in the diagnosis of its sequelae and can predict the prognosis of its outcome. TCD is a cost-effective, reliable modality for diagnosing vasculopathy associated with bacterial meningitis. It may prove useful in our armamentarium of management. Large prospective studies with long-term follow-up data may help establish the use of TCD in bacterial meningitis.


Assuntos
Meningites Bacterianas , Ultrassonografia Doppler Transcraniana , Humanos , Adulto , Ultrassonografia Doppler Transcraniana/métodos , Estudos Prospectivos , Meningites Bacterianas/complicações , Meningites Bacterianas/diagnóstico por imagem , Prognóstico , Velocidade do Fluxo Sanguíneo
19.
Eur J Pediatr ; 183(3): 1059-1072, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38112802

RESUMO

Point-of-care brain ultrasound and transcranial doppler or color-coded doppler is being increasingly used as an essential diagnostic and monitoring tool at the bedside of critically ill neonates and children. Brain ultrasound has already established as a cornerstone of daily practice in the management of the critically ill newborn for diagnosis and follow-up of the most common brain diseases, considering the easiness to insonate the brain through transfontanellar window. In critically ill children, doppler based techniques are used to assess cerebral hemodynamics in acute brain injury and recommended for screening patients suffering from sickle cell disease at risk for stroke. However, more evidence is needed regarding the accuracy of doppler based techniques for non-invasive estimation of cerebral perfusion pressure and intracranial pressure, as well as regarding the accuracy of brain ultrasound for diagnosis and monitoring of acute brain parenchyma alterations in children. This review is aimed at providing a comprehensive overview for clinicians of the technical, anatomical, and physiological basics for brain ultrasonography and transcranial doppler or color-coded doppler, and of the current status and future perspectives of their clinical applications in critically ill neonates and children. CONCLUSION: In critically ill neonates, brain ultrasound for diagnosis and follow-up of the most common cerebral pathologies of the neonatal period may be considered the standard of care. Data are needed about the possible role of doppler techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles. In pediatric critical care, doppler based techniques should be routinely adopted to assess and monitor cerebral hemodynamics. New technologies and more evidence are needed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles. WHAT IS KNOWN: • In critically ill neonates, brain ultrasound for early diagnosis and follow-up of the most common cerebral and neurovascular pathologies of the neonatal period is a cornerstone of daily practice. In critically ill children, doppler-based techniques are more routinely used to assess cerebral hemodynamics and autoregulation after acute brain injury and to screen patients at risk for vasospasm or stroke (e.g., sickle cell diseases, right-to-left shunts). WHAT IS NEW: • In critically ill neonates, research is currently focusing on the use of novel high frequency probes, even higher than 10 MHz, especially for extremely preterm babies. Furthermore, data are needed about the role of doppler based techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles, also integrated with a non-invasive assessment of brain oxygenation. In pediatric critical care, new technologies should be developed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles. Furthermore, large multicenter studies are needed to clarify role and accuracy of doppler-based techniques to assess cerebral perfusion pressure and its changes after treatment interventions.


Assuntos
Lesões Encefálicas , Acidente Vascular Cerebral , Recém-Nascido , Humanos , Criança , Sistemas Automatizados de Assistência Junto ao Leito , Estado Terminal , Ultrassonografia , Ultrassonografia Doppler Transcraniana/métodos , Encéfalo/diagnóstico por imagem , Lesões Encefálicas/diagnóstico por imagem
20.
Artigo em Inglês | MEDLINE | ID: mdl-38083229

RESUMO

Transcranial doppler (TCD) ultrasound probes are an invaluable tool in cerebral blood flow (CBF) studies. Their operation demands maintaining consistent pose on the subject throughout the experimental protocol. However, the displacement of the TCD probe during vestibular studies is common and substantially prolongs the experiment or even terminates it. This is a significant challenge for integrating motion-based vestibular studies with CBF investigations. In response, a mechatronics system is designed to allow remote repositioning of the TCD probe during data collection experiments while the subject is wearing a head mounted virtual reality (VR) display and seated in a vestibular disorientation device. This paper presents the design, prototype, and operation of this mechatronics apparatus.Clinical Relevance- The mechatronics apparatus of this paper can enable motion-based vestibular studies that entail the use of CBF velocity measurement and head-mounted virtual reality display.


Assuntos
Vestíbulo do Labirinto , Realidade Virtual , Ultrassonografia Doppler Transcraniana/métodos , Circulação Cerebrovascular/fisiologia , Vestíbulo do Labirinto/diagnóstico por imagem , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA